Attenuation and Average Power Ratings
 
 
Frequency
MHz
Attenuation
dB /100 ft
Attenuation
dB/100 m
Average Power, kW  
         
30 1.9 6.1 0.85
50 2.5 8.0 0.66
150 4.3 13.9 0.38
220 5.1 16.9 0.31
450 7.4 24.4 0.21
900 10.6 34.7 0.15
1500 13.8 45.1 0.11
1800 15.1 49.6 0.10
2000 15.9 52.5 0.10
2500 17.9 58.9 0.09
       
Standard Conditions :
For Attenuation :
VSWR 1.0, ambient temperature 200C (680F).
For Average Power : VSWR 1.0, ambient temperature 400C (1040F) Inner conductor temperature 1000C (2120F), sea level, dry air, atmospheric pressure, no solar loading
       
 
 
Description
 
Standard Outdoor Cable, Polyethylene Jacket

CNT-195

 
Watertight Cable, Polyethylene Jacket

CNT-195-DB

 
Mechanical
 
Minimum Bending Radius, In (mm)
Bending Moment, lb-ft (N•m)
Cable Weight, lb/ft (kg/m)
Tensile Strength, lb (kg)
Flat Plate Crush Strength, lb/in (kg/mm)

0.5 (12.7)
0.2 (0.27)
0.021 (0.03)
40 (18.2)
15 (0.27)
 
Construction Materials
 
Inner Conductor
Dielectric
Outer Conductor
Overall Braid
Solid BC
Foam Polyethylene
Aluminum Tape
Tinned Copper
 
Dimensions
 
Diameter Inner Conductor, in (mm)
Diameter Dielectric, in (mm)
Diameter Outer Conductor, in (mm)
Diameter Overall Braid, in (mm)
Diameter over Jacket, in (mm)
0.037 (0.94)
0.113 (2.87)
0.118 (3.00)
0.141 (3.58)
0.195 (4.95)
 
Environmental
 
Storage Temperature, 0C (0F)
Installation Temperature, 0C (0F)
Operating Temperature, 0C (0F)       
-70 to +85 (-94 to +185)
-40 to +85 (-40 to +185)
-40 to +85 (-40 to +185)
 

Electrical

 
Maximum Frequency, GHz
Velocity, percent  
dc Breakdown, Volts
Peak Power Rating, kW

dc Resistance, ohms/1000 ft (1000m)
    Inner Conductor
    Outer Conductor
Jacket Spark, volts RMS    
Capacitance, pF/ft (m)
Inductance, mH/ft (m)
Shielding Effectiveness, dB
Phase Stability, ppm/0C       
41
80
1000
2.5


7.6 (29.94)
4.9 (16.08)
3000
24.3 (79.7)
0.064 (0.21)
>90
<10
 
top
 
  Interface Description Part Number Coupling Nut Inner Contact Attachment Outer Contact Attachment Finish Body/Pin
  N Male Straight 195 PNM-H Hex Solder Clamp T /G
  TNC Male Straight 195 PTM Hex Solder Clamp T /G
  TNC Female Straight 195 PTF NA Solder Clamp T /G
  SMA Male Straight 195 PSM-CR Hex Solder Crimp SS
  SMA Male Right Angle 195 PSM-CR Hex Solder Crimp SS
               
   
   
Cables : RF Coaxial & Microwaves Cables : Heliax Cable : LDF 1-50 Cable: LDF 2-50 Cable : LDF 4-50 Cable:
LDF 4-5.50 Cable: LDF 5-50A Cable: VXL 5-50A Cable : FSJ Series Cables: FSJ 1-50A Cable: FSJ 2-50A Cable: FSJ 4-50B Cable: LMR Series Cables LMR - 100A Cable: LMR - 195 Cable: LMR 200 Cable: LMR 240 Cable:
LMR 240-75 Cable : LMR 400A Cable: LMR 400-75 Cable: LMR 500 Cable: LMR 600 Cable: LMR 900 Cable:
LMR 1200 Cable: LMR 1700 Cable
 
Keywords Heliax Cable, LDF Cable, Collinear Antenna , Yagi Antenna , Seling Antenna , XLR Connectors , RF Coaxial Connectors Links | Design Credits : adesigncafe.com