| Description |
| |
Cable Ordering Information
Standard Superflexible Cable
1/4'” Standard Cable, Standard Jacket
fire Retardant Cables
1/4" Fire Retardant Jacket (CATVX)
1/4" Fire Retardant Jacket (CATVR)
Low VSWR and Specialized Cables
1/4" Low VSWR, specify operating band Phase
Stabilized and Phase Measured Cable
Jumper Cable Assemblies |
FSJ1-50A
FSJ1RN-50B
FSJ1RN-50B
FSJ1P-50-(**) |
| |
Characteristics Electrical Impedance, ohms
Maximum Frequency, GHz
Velocity, percent
Peak Power Rating, Kw
Dc Resistance, ohms/1000ft(1000m)
Inner
Outer
Dc Breakdown, volts
Jacket Spark, volts
Capacitance, Pf/ ft(m)
Inductance, Ph/ ft(m) |
50 +- 1
20.4
84
6.4
3.0(9.8)
2.0(6.5)
1600
5000
24.2(79.4)
0.061(0.200)
|
| |
| Mechanical |
| |
Outer conductor
Inner Conductor
Diameter over Jacket, in (mm)
Diameter over Jacket,fire-retardant jacket,in (mm)
Diameter over Copper outer Conductor, in(mm)
Diameter Inner Conductor, in (mm)
Minimum Bending Radius, in(mm)
Number of Bends, minimum (typical) Bending Moment, lb-ft (N.m)
Cable Weight, lb/ft(kg/m)
Tesile strength, lb(kg)
Flat Plate Crush Strength, lb/in(kg/mm) |
Copper
Cu-Clad Al
0.29(7.4)
0.29(7.4)
0.25(6.4)
0.075(1.9)
1(25)
15(20)
0.8(1.1)
0.045(0.067)
150(68)
100(1.8) |
| |
|
|
 |